| Delavan PowerFLO 5800 Series 5.3 gpm 60 psi (115 VOLT) | Specifications
Motor Type: 115 VAC with 4' cord and plug, totally enclosed, non-ventilated
Leads: 14 AWG, 12” long
Duty Cycle: See Heat Rise graph below
Temperature Limits: Motor is not equipped with thermal protection. For user safety, optimal performance, and maximum motor life, the motor surface temperature should not exceed 180°F (82°C) (See Heat Rise graph below).
Pump Type: 5 chamber positive displacement diaphragm pump, self priming, capable of being run dry, demand or bypass mode
Certifications: NSF Standard 58
Liquid Temperature: 140°F (60°C) Max.
Priming Capabilities: 14 feet (4 m)
Max Pressure: 60 PSI
Inlet/Outlet Ports: 1/2” FNPT
Materials of Construction
Housings: Polypropylene
Valves: Viton
Diaphragm: Santoprene
Fasteners: Stainless steel
| | |